{"id":839,"date":"2026-06-02T21:50:39","date_gmt":"2026-06-02T20:50:39","guid":{"rendered":"https:\/\/loxoneworks.cz\/?p=839"},"modified":"2026-06-02T22:01:51","modified_gmt":"2026-06-02T21:01:51","slug":"dahua-dss-express-8-8-zakladni-nastaveni-cast-1","status":"publish","type":"post","link":"https:\/\/loxoneworks.cz\/?p=839","title":{"rendered":"Dahua DSS Express 8.8 &#8211; z\u00e1kladn\u00ed nastaven\u00ed &#8211; \u010d\u00e1st 1"},"content":{"rendered":"<p><!-- GUTENBERG BLOCK MARKUP \u2013 zkop\u00edrovat cel\u00fd obsah, vlo\u017eit do WordPress editoru (Ctrl+V) --><\/p>\n\n\n<p class=\"wp-block-paragraph\">Tato s\u00e9rie \u010dl\u00e1nk\u016f vznik\u00e1 trochu neobvykle \u2013 p\u00ed\u0161u ji z\u00e1rove\u0148 jako pr\u016fvodce pro \u010dten\u00e1\u0159e i jako vlastn\u00ed pozn\u00e1mky. Dahua DSS Express se u\u010d\u00edm za pochodu, prvn\u00ed instalaci provozuji na star\u00e9m serveru, kter\u00fd mi zbyl (politika re-use m\u00edsto n\u00e1kupu nov\u00e9ho HW). \u010casem pl\u00e1nuji \u010distou instalaci na lep\u0161\u00edm hardwaru \u2013 bazarov\u00fd 2\u00d7 Xeon s 64 GB RAM vyjde na jednotky tis\u00edc korun. Stejn\u011b tak budu syst\u00e9m roz\u0161i\u0159ovat o dal\u0161\u00ed budovy, tak\u017ee i tento seri\u00e1l bude postupn\u011b dor\u016fstat. Ve\u0161ker\u00e1 nastaven\u00ed jsem d\u011blal s nulov\u00fdmi znalostmi DSS (nicm\u00e9n\u011b produkty Dahua zn\u00e1m pom\u011brn\u011b dob\u0159e) metodou pokus\/omyl za \u00fa\u017easn\u00e9 asistence ze strany Claude AI.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aktu\u00e1ln\u00ed rozsah: 2 budovy, 6 dve\u0159n\u00edk\u016f VTO (z toho 4 zat\u00edm nakonfigurovan\u00e9), 1 p\u0159\u00edstupov\u00fd kontrol\u00e9r ASC2204, \u010dte\u010dky ASR2100A na intern\u00edch dve\u0159\u00edch a NVR Dahua 5216-EI2. Pokud vid\u00edte chybu nebo m\u00e1te jin\u00e9 zku\u0161enosti, pi\u0161te do koment\u00e1\u0159\u016f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Co nahrazujeme a pro\u010d<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">V objektu byl provozov\u00e1n p\u0159\u00edstupov\u00fd syst\u00e9m na b\u00e1zi \u010dte\u010dek Wiegand 125 kHz \u0159\u00edzen\u00fdch zabezpe\u010dovac\u00ed \u00fast\u0159ednou st\u00e1\u0159\u00ed p\u0159es 25 let. Funk\u010dn\u00ed, ale bez jak\u00e9koli mo\u017enosti centr\u00e1ln\u00ed spr\u00e1vy, report\u016f nebo integrace s kamerov\u00fdm syst\u00e9mem. P\u0159i v\u00fdm\u011bn\u011b jsme museli dohledat, kam vede kter\u00fd kabel \u2013 na\u0161t\u011bst\u00ed k dve\u0159n\u00edk\u016fm byl nata\u017een klasick\u00fd CAT5e, tak\u017ee dve\u0159n\u00edky VTO jedou p\u0159es PoE. Pro z\u00e1mky je p\u0159ivedeno extern\u00ed nap\u00e1jen\u00ed +12V, i kdy\u017e to nen\u00ed v\u017edy nutn\u00e9 \u2013 v p\u0159\u00edpad\u011b n\u00edzkoodb\u011brov\u00fdch z\u00e1mk\u016f dok\u00e1\u017ee dve\u0159n\u00edk poskytnout 12V p\u0159\u00edmo z PoE nap\u00e1jen\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Co je Dahua DSS Express a pro\u010d ho pou\u017e\u00edt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dahua DSS Express je okle\u0161t\u011bn\u00e1 (ale pro v\u011bt\u0161inu instalac\u00ed pln\u011b dosta\u010duj\u00edc\u00ed) verze DSS Pro. Z\u00e1klad je zdarma a zahrnuje a\u017e <strong>64 kamerov\u00fdch kan\u00e1l\u016f<\/strong>, 8 ANPR kan\u00e1l\u016f a 8 kan\u00e1l\u016f rozpozn\u00e1v\u00e1n\u00ed obli\u010dej\u016f. Pokud pot\u0159ebujete v\u00edce kamer, dokupuj\u00ed se licence po kan\u00e1lech a\u017e do maxima 256 \u2013 nad tuto hranici je nutn\u00fd DSS Pro. Krom\u011b kamer se dokupuj\u00ed moduly pro konkr\u00e9tn\u00ed funkce (viz Licence n\u00ed\u017ee).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00edsto konfigurace ka\u017ed\u00e9ho za\u0159\u00edzen\u00ed zvl\u00e1\u0161\u0165 spravujete kamery, p\u0159\u00edstupov\u00fd syst\u00e9m, dve\u0159n\u00edky a rozpozn\u00e1v\u00e1n\u00ed obli\u010dej\u016f z jednoho m\u00edsta. Pro instalaci s v\u00edce budovami nebo v\u00edce typy za\u0159\u00edzen\u00ed je DSS prakticky nutnost \u2013 bez n\u011bj byste \u010dipy, osoby a p\u0159\u00edstupov\u00e1 pr\u00e1va konfigurovali na ka\u017ed\u00e9m kontrol\u00e9ru zvl\u00e1\u0161\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aktu\u00e1ln\u011b provozuji verzi <strong>DSS Express 8.8<\/strong> (instalace kv\u011bten 2026).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Hardware a opera\u010dn\u00ed syst\u00e9m<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Provozuji DSS Express na sta\u0159i\u010dk\u00e9m Dell PowerEdge R210 II (Xeon E3-1220, 8 GB ECC RAM, SSD 512 GB pro syst\u00e9m + SSD 1 TB pro data) s Windows 11. Je to pragmatick\u00e9 \u0159e\u0161en\u00ed \u2013 server jsem m\u011bl k dispozici a Windows 11 funguje. Ale je to skute\u010dn\u00e9 minimum:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>RAM 8 GB je absolutn\u00ed spodn\u00ed hranice.<\/strong> DSS Express samotn\u00fd se na pr\u00e1zdn\u00e9m syst\u00e9mu vejde, ale jakmile p\u0159ibude Face Recognition, p\u0159\u00edstupov\u00fd syst\u00e9m a dve\u0159n\u00edky, bude to t\u011bsn\u00e9. Doporu\u010duji rovnou 16 GB &#8211; j\u00e1 u\u017e jsem roz\u0161\u00ed\u0159il. Zde mal\u00e1 pozn\u00e1mka: tento server podporuje ne zcela roz\u0161\u00ed\u0159en\u00e9 moduly DDR3 ECC UDIMM (ne RDIMM), ale daj\u00ed se st\u00e1le sehnat. Aktu\u00e1ln\u00ed cena na Bazo\u0161i za cel\u00fd server (bez SSD disk\u016f) je cca 2.000 K\u010d.<\/li>\n\n\n\n<li><strong>Windows 11 nen\u00ed ide\u00e1ln\u00ed volba pro server.<\/strong> Licen\u010dn\u011b ani technicky nen\u00ed ur\u010den pro 24\/7 provoz. Pro \u010distou instalaci doporu\u010duji Windows Server \u2013 i star\u0161\u00ed verze (2019) na bazarov\u00e9m HW vyjde levn\u011b a zbav\u00edte se omezen\u00ed.<\/li>\n\n\n\n<li><strong>Video stream neproch\u00e1z\u00ed serverem.<\/strong> Pokud ukl\u00e1d\u00e1te z\u00e1znamy na NVR (a tak to m\u00e1 b\u00fdt), server zpracov\u00e1v\u00e1 jen metadata, snapshoty a datab\u00e1zi osob. N\u00e1roky na CPU a disk jsou tedy p\u0159ekvapiv\u011b n\u00edzk\u00e9.<\/li>\n\n\n\n<li><strong>Pagefile nastavte ru\u010dn\u011b<\/strong> na datov\u00e9m disku: Sysdm.cpl \u2192 Up\u0159esnit \u2192 V\u00fdkon \u2192 Virtu\u00e1ln\u00ed pam\u011b\u0165 \u2192 vlastn\u00ed velikost 8 192 \/ 16 384 MB. DSS si ho vy\u017eaduje v\u011bt\u0161\u00ed, ne\u017e Windows nastav\u00ed automaticky.<\/li>\n\n\n\n<li><strong>iDRAC<\/strong> (vzd\u00e1len\u00e1 spr\u00e1va Dell) je pro server bez monitoru k nezaplacen\u00ed \u2013 p\u0159\u00edstup ke konzoli, restart, BIOS, v\u0161e p\u0159es s\u00ed\u0165.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Rozd\u011blen\u00ed datov\u00e9ho disku<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1TB datov\u00fd SSD jsem rozd\u011blil ve Spr\u00e1vci disk\u016f Windows (diskmgmt.msc) na dv\u011b \u010d\u00e1sti:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>D: ~200 GB<\/strong> \u2013 video fallback (z\u00e1loha pro p\u0159\u00edpad v\u00fdpadku NVR)<\/li>\n\n\n\n<li><strong>E: ~800 GB<\/strong> \u2013 Images and Files (snapshoty, fotky osob, z\u00e1znamy FR, ANPR fotky)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PostgreSQL datab\u00e1ze DSS z\u016fst\u00e1v\u00e1 na C:\\DSS \u2013 tam ji instal\u00e1tor um\u00edst\u00ed automaticky. V nastaven\u00ed DSS: <strong>Local Config \u2192 Storage<\/strong> \u2192 p\u0159idat D: jako Video, E: jako Images and Files. Retention toggle v DSS vypn\u011bte \u2013 nechte kapacitu spravovat NVR p\u0159es FIFO p\u0159episov\u00e1n\u00ed. Pokud retention v DSS zapnete, budou p\u0159i pln\u011bn\u00ed disku hl\u00e1\u0161eny chyby.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instalace DSS Express<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Instal\u00e1tor st\u00e1hn\u011bte z Dahua support centra nebo partnersk\u00e9ho port\u00e1lu. Instalace nevy\u017eaduje \u017e\u00e1dn\u00e1 speci\u00e1ln\u00ed nastaven\u00ed \u2013 v\u0161e se um\u00edst\u00ed do C:\\DSS v\u010detn\u011b PostgreSQL datab\u00e1ze. DSS pot\u00e9 b\u011b\u017e\u00ed jako sada Windows slu\u017eeb (viditeln\u00e9 v Services.msc jako DSS*).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159ihl\u00e1\u0161en\u00ed prob\u00edh\u00e1 p\u0159es webov\u00fd prohl\u00ed\u017ee\u010d (HTTPS na IP serveru) nebo p\u0159es DSS Client aplikaci. Doporu\u010duji webov\u00e9 rozhran\u00ed \u2013 je aktu\u00e1ln\u011bj\u0161\u00ed a dostupn\u00e9 odkudkoli v s\u00edti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Licence<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1kladn\u00ed verze DSS Express je zdarma \u2013 64 kamerov\u00fdch kan\u00e1l\u016f, ANPR a FR v z\u00e1kladu. Dokupuj\u00ed se pouze moduly pro konkr\u00e9tn\u00ed typy za\u0159\u00edzen\u00ed. Ceny jsou v \u0159\u00e1du ni\u017e\u0161\u00edch stovek korun za kus (cca 400 K\u010d), p\u0159i\u010dem\u017e VDP a D licence maj\u00ed stejnou cenu. Pro moji instalaci jsou pot\u0159eba:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>DSS8-EXVDP<\/strong> \u2013 1 licence = 1 VTO dve\u0159n\u00edk nebo VTH monitor. <em>Bez t\u00e9to licence nelze VTO do DSS p\u0159idat v\u016fbec.<\/em> Pro 6 VTO a 1 VTH = 7 kus\u016f.<\/li>\n\n\n\n<li><strong>DSS8-EXD<\/strong> \u2013 licence pro p\u0159\u00edstupov\u00fd kontrol\u00e9r (1 licence = 1 dve\u0159n\u00ed kan\u00e1l). <em>Bez n\u00ed nelze ACS p\u0159idat do DSS.<\/em> Pro ASC2204 (4 kan\u00e1ly) = 4 kusy.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aktivace: <strong>General \u2192 License<\/strong> v DSS administraci. Licence jsou v\u00e1zan\u00e9 na konkr\u00e9tn\u00ed instalaci DSS (Hardware ID), nikoliv na konkr\u00e9tn\u00ed za\u0159\u00edzen\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">P\u0159id\u00e1n\u00ed za\u0159\u00edzen\u00ed \u2013 obecn\u00fd princip a ConfigTool<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">V\u0161echna za\u0159\u00edzen\u00ed se p\u0159id\u00e1vaj\u00ed p\u0159es <strong>Device Manager \u2192 Add Device<\/strong>: IP adresa, port, p\u0159ihla\u0161ovac\u00ed \u00fadaje. P\u0159ed p\u0159id\u00e1n\u00edm do DSS ale mus\u00ed b\u00fdt za\u0159\u00edzen\u00ed inicializovan\u00e9 \u2013 nastaven\u00e9 heslo a s\u00ed\u0165ov\u00e9 parametry. K tomu slou\u017e\u00ed Dahua <strong>ConfigTool<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pot\u0159ebn\u00e1 verze ConfigToolu: <strong>V5.001.0000006.2<\/strong> nebo nov\u011bj\u0161\u00ed. Star\u0161\u00ed verze zp\u016fsobuje probl\u00e9m s inicializac\u00ed p\u0159\u00edstupov\u00e9ho kontrol\u00e9ru (viz n\u00ed\u017ee).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peky s heslem ASC kontrol\u00e9ru v ConfigToolu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Star\u0161\u00ed verze ConfigToolu vy\u017eadovala p\u0159i inicializaci alfanumerick\u00e9 heslo (minim\u00e1ln\u011b 8 znak\u016f, kombinace \u010d\u00edslic a p\u00edsmen) \u2013 stejn\u011b jako u IP kamer. ASC2204 ale um\u00ed pouze numerick\u00e9 heslo. V\u00fdsledek: inicializace v\u017edy skon\u010dila chybou bez zjevn\u00e9ho d\u016fvodu. \u0158e\u0161en\u00ed p\u0159inesl a\u017e upgrade na nejnov\u011bj\u0161\u00ed ConfigTool, kter\u00fd u kontrol\u00e9r\u016f ASC spr\u00e1vn\u011b vy\u017eaduje pouze numerick\u00e9 heslo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Druh\u00fd \u0161pek: ConfigTool zad\u00e1v\u00e1 heslo p\u0159i samotn\u00e9m vyhled\u00e1v\u00e1n\u00ed za\u0159\u00edzen\u00ed v s\u00edti. Proto\u017ee kamery maj\u00ed alfanumerick\u00e9 heslo a ASC kontrol\u00e9r numerick\u00e9, nelze je prohled\u00e1vat v jednom pr\u016fchodu \u2013 je nutn\u00e9 spustit hled\u00e1n\u00ed dvakr\u00e1t, poka\u017ed\u00e9 s jin\u00fdm heslem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">NVR \u2013 p\u0159idejte NVR, ne jednotliv\u00e9 kamery<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Do DSS p\u0159idejte NVR jako jedno za\u0159\u00edzen\u00ed (IP, port 37777). Kamery se automaticky objev\u00ed jako kan\u00e1ly tohoto NVR. Pokud p\u0159id\u00e1te kamery samostatn\u011b, vznikaj\u00ed duplicitn\u00ed streamy a z\u00e1znamy se nespr\u00e1vn\u011b routuj\u00ed. T\u00e9matu NVR se budu v\u011bnovat v samostatn\u00e9m \u010dl\u00e1nku.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159\u00edstupov\u00fd kontrol\u00e9r a \u010dte\u010dky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Po inicializaci p\u0159es ConfigTool p\u0159idejte ASC2204 p\u0159es Device Manager. V DSS se pot\u00e9 zp\u0159\u00edstupn\u00ed modul Access Control s p\u0159ehledem dve\u0159n\u00edch kan\u00e1l\u016f kontrol\u00e9ru. K jednotliv\u00fdm dve\u0159\u00edm jsou p\u0159ipojeny \u010dte\u010dky <strong>ASR2100A<\/strong> \u2013 p\u0159es rozhran\u00ed RS-485 nebo Wiegand na svorkovnici kontrol\u00e9ru. \u010cte\u010dky se do DSS nep\u0159id\u00e1vaj\u00ed samostatn\u011b, jsou sou\u010d\u00e1st\u00ed kan\u00e1lu dan\u00e9ho kontrol\u00e9ru.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VTH monitor \u2013 nejd\u0159\u00edv, ne\u017e VTO<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">VTH monitor doporu\u010duji p\u0159idat a nakonfigurovat <strong>p\u0159ed<\/strong> nastaven\u00edm tla\u010d\u00edtek na VTO. P\u0159i\u0159azen\u00ed c\u00edlov\u00e9ho \u010d\u00edsla tla\u010d\u00edtku na VTO je mo\u017en\u00e9 a\u017e po prob\u011bhnut\u00ed Contacts Sync \u2013 a k tomu je pot\u0159eba m\u00edt VTH registrovan\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">VTH5221D-S2 nem\u00e1 plnohodnotn\u00e9 webov\u00e9 rozhran\u00ed pro SIP nastaven\u00ed \u2013 parametry se nastavuj\u00ed p\u0159es ConfigTool nebo p\u0159\u00edmo na dotykov\u00e9 obrazovce. Kl\u00ed\u010dov\u00e9 nastaven\u00ed: SIP port. VTH m\u011bl v\u00fdchoz\u00ed port <strong>5060<\/strong>, zat\u00edmco DSS SIP server naslouch\u00e1 na <strong>5080<\/strong>. Po oprav\u011b tohoto portu v ConfigToolu VTH okam\u017eit\u011b zaregistroval.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">VTH v DSS dostane room number <strong>9901<\/strong>. Ozna\u010den\u00ed #0 (tedy 9901#0) se m\u016f\u017ee objevit v ConfigToolu jako zobrazen\u00ed hlavn\u00edho monitoru, ale samotn\u00e9 \u010d\u00edslo zadan\u00e9 v konfiguraci je 9901.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Network Terminals \u2013 povinn\u00e9 p\u0159id\u00e1n\u00ed v\u0161ech VTO do VTH<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tady jsem ztratil pom\u011brn\u011b dost \u010dasu. Ve VTH konfiguraci (ConfigTool \u2192 Device Config \u2192 Network Terminals) je nutn\u00e9 ru\u010dn\u011b zadat v\u0161echny VTO dve\u0159n\u00edky, se kter\u00fdmi m\u00e1 VTH komunikovat. Bez tohoto kroku VTH dve\u0159n\u00edky \u201enezn\u00e1&#8220; a hovor nep\u0159ijme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nastaven\u00ed se skl\u00e1d\u00e1 z:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Main VTO<\/strong> \u2013 prim\u00e1rn\u00ed dve\u0159n\u00edk (typicky ten fyzicky nebo logicky nejbli\u017e\u0161\u00ed VTH monitoru). Zad\u00e1te n\u00e1zev, IP adresu, u\u017eivatelsk\u00e9 jm\u00e9no a heslo VTO, za\u0161krtnete VTO Enable Status.<\/li>\n\n\n\n<li><strong>Sub VTO 1 a\u017e Sub VTO 19<\/strong> \u2013 ostatn\u00ed dve\u0159n\u00edky instalace. Stejn\u00e9 parametry jako u Main VTO. Sloty Sub VTO 1\u201319 jsou tedy pro dal\u0161\u00ed dve\u0159n\u00edky, nikoliv pro pod\u0159\u00edzen\u00e9 monitory \u2013 to m\u011b zpo\u010d\u00e1tku zm\u00e1tlo.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">V m\u00e9m p\u0159\u00edpad\u011b: Main VTO = Dve\u0159n\u00edk 2NP (192.168.8.64), Sub VTO 1 = Dve\u0159n\u00edk 1NP (192.168.8.63), a tak d\u00e1le pro ka\u017ed\u00fd dve\u0159n\u00edk v instalaci. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"361\" src=\"https:\/\/loxoneworks.cz\/wp-content\/uploads\/2026\/06\/image-1024x361.png\" alt=\"\" class=\"wp-image-840\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"355\" src=\"https:\/\/loxoneworks.cz\/wp-content\/uploads\/2026\/06\/image-1-1024x355.png\" alt=\"\" class=\"wp-image-841\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Contacts Sync \u2013 povinn\u00fd krok<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Po registraci VTH spus\u0165te <strong>Contacts Sync<\/strong> v DSS (Video Intercom \u2192 Call Management). Tento krok prop\u00ed\u0161e seznam room numbers do v\u0161ech VTO \u2013 bez n\u011bj z\u016fstanou dropdowny pro p\u0159i\u0159azen\u00ed tla\u010d\u00edtek pr\u00e1zdn\u00e9 a VTO nezn\u00e1 c\u00edle pro sm\u011brov\u00e1n\u00ed hovor\u016f. Tady jsem ztratil hodn\u011b \u010dasu, ne\u017e jsem na tuto z\u00e1vislost p\u0159i\u0161el.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dve\u0159n\u00edky VTO \u2013 konfigurace p\u0159es webov\u00e9 rozhran\u00ed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dve\u0159n\u00edky VTO4202FB-P-S3 jsem konfiguroval p\u0159es jejich webov\u00e9 rozhran\u00ed (IP adresa v prohl\u00ed\u017ee\u010di). VTO4202FB je modul\u00e1rn\u00ed dve\u0159n\u00edk \u2013 sest\u00e1v\u00e1 z hlavn\u00edho modulu s kamerou a p\u0159\u00eddavn\u00fdch modul\u016f (v m\u00e9m p\u0159\u00edpad\u011b tla\u010d\u00edtkov\u00e9 panely a \u010dte\u010dka karet).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Layout \u2013 nejd\u0159\u00edv poskl\u00e1dat modul<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ne\u017e p\u0159istoup\u00edte k nastaven\u00ed tla\u010d\u00edtek, mus\u00edte v sekci <strong>Local Device Config &#8211;  Layout<\/strong> definovat fyzick\u00e9 slo\u017een\u00ed panelu: kter\u00e9 moduly jsou osazeny a v jak\u00e9m po\u0159ad\u00ed. Bez tohoto kroku nejsou tla\u010d\u00edtka v nastaven\u00ed viditeln\u00e1. \u010c\u00edsla tla\u010d\u00edtek v\u0161ak budete nastavovat pozd\u011bji &#8211; viz d\u00e1le.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"491\" height=\"694\" src=\"https:\/\/loxoneworks.cz\/wp-content\/uploads\/2026\/06\/image-3.png\" alt=\"\" class=\"wp-image-847\" srcset=\"https:\/\/loxoneworks.cz\/wp-content\/uploads\/2026\/06\/image-3.png 491w, https:\/\/loxoneworks.cz\/wp-content\/uploads\/2026\/06\/image-3-300x424.png 300w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">SIP server \u2013 DSS, ne master VTO<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dve\u0159n\u00edky Dahua podporuj\u00ed dva SIP re\u017eimy:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Jeden VTO jako master, ostatn\u00ed pod\u0159\u00edzen\u00e9<\/strong> \u2013 bez extern\u00edho serveru, ale ve\u0161ker\u00e1 logika le\u017e\u00ed na master VTO. Nevhodn\u00e9 pro centralizovanou spr\u00e1vu.<\/li>\n\n\n\n<li><strong>Extern\u00ed SIP server<\/strong> \u2013 ka\u017ed\u00fd VTO se registruje jako SIP klient. V na\u0161em p\u0159\u00edpad\u011b je SIP serverem DSS Express.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Chceme druhou variantu. V sekci <strong>Network \u2192 SIP Server<\/strong> na ka\u017ed\u00e9m VTO:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Server Type: <strong>Private SIP Server<\/strong><\/li>\n\n\n\n<li>Server IP: IP adresa DSS serveru<\/li>\n\n\n\n<li>Port: <strong>5080<\/strong><\/li>\n\n\n\n<li>SIP Domain: <strong>VDP<\/strong><\/li>\n\n\n\n<li>SIP No.: unik\u00e1tn\u00ed \u010d\u00edslo ka\u017ed\u00e9ho VTO (8001, 8002, 8003\u2026)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Port 5080 a dom\u00e9na VDP jsou pevn\u011b dan\u00e9 \u2013 nelze je zm\u011bnit. Na VTO4202FB byl v\u00fdchoz\u00ed port ji\u017e 5080, tak\u017ee nebylo t\u0159eba ho m\u011bnit. U jin\u00fdch model\u016f b\u00fdv\u00e1 v\u00fdchoz\u00ed 5060.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u016fle\u017eit\u00e9 upozorn\u011bn\u00ed: DSS SIP server je uzav\u0159en\u00e1 Dahua implementace. Registrovat lze pouze Dahua VTO a VTH za\u0159\u00edzen\u00ed. Cisco, Fanvil, Yealink ani jin\u00e9 SIP telefony se na DSS SIP server zaregistrovat nemohou \u2013 pro hybridn\u00ed nasazen\u00ed je nutn\u00e1 samostatn\u00e1 SIP \u00fast\u0159edna (FreePBX, Asterisk).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Typ za\u0159\u00edzen\u00ed a Building\/Unit nastaven\u00ed<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159i p\u0159id\u00e1v\u00e1n\u00ed VTO do DSS mus\u00ed b\u00fdt nastaven spr\u00e1vn\u00fd typ za\u0159\u00edzen\u00ed \u2013 pro modul\u00e1rn\u00ed \u0159adu VTO42xx je to <strong>Villa Station<\/strong>. Z\u00e1rove\u0148 v DSS mus\u00ed b\u00fdt glob\u00e1ln\u00ed nastaven\u00ed interkomu konzistentn\u00ed: Building OFF \/ Unit OFF pro instalace bez hierarchick\u00e9 struktury budova\u2192jednotka.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nesoulad zp\u016fsobuje chybu <em>\u201eBuilding enable not matched&#8220;<\/em> a VTO p\u0159ech\u00e1z\u00ed do offline stavu i p\u0159esto, \u017ee je pingable. Po oprav\u011b restartujte DSS slu\u017eby.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159i\u0159azen\u00ed tla\u010d\u00edtek<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Po Contacts Sync p\u0159ejd\u011bte v webov\u00e9m rozhran\u00ed VTO do <strong>Button Settings<\/strong>. Ka\u017ed\u00e9mu tla\u010d\u00edtku p\u0159i\u0159ad\u00edte room number c\u00edlov\u00e9ho VTH monitoru nebo skupiny. Dokud Contacts Sync neprob\u011bhne, jsou dropdowny pr\u00e1zdn\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Restart DSS slu\u017eeb<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Po zm\u011bn\u00e1ch v konfiguraci Building\/Unit nebo p\u0159i v\u00fdpadku komunikace restartujte DSS p\u0159es PowerShell:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Restart-Service -Name \"DSS*\" -Force<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159\u00edpadn\u011b p\u0159es Services.msc \u2013 vyhledejte v\u0161echny slu\u017eby za\u010d\u00ednaj\u00edc\u00ed DSS. Po restartu ov\u011b\u0159te stav za\u0159\u00edzen\u00ed v Device Manager.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Co d\u00e1l<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Po dokon\u010den\u00ed z\u00e1kladn\u00ed konfigurace by m\u011bl stav vypadat takto: DSS nainstalov\u00e1n a \u00falo\u017ei\u0161t\u011b nakonfigurov\u00e1no, licence aktivov\u00e1ny, NVR p\u0159id\u00e1n a kamery viditeln\u00e9 jako kan\u00e1ly, ASC kontrol\u00e9r p\u0159id\u00e1n, VTH registrov\u00e1n a Contacts Sync hotov, VTO dve\u0159n\u00edky registrov\u00e1ny na DSS SIP server a tla\u010d\u00edtka p\u0159i\u0159azena.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pokud m\u00e1te v\u0161e nastaveno, m\u011blo by j\u00edt zavolat z VTO na VTH a naopak.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V dal\u0161\u00ed \u010d\u00e1sti se zam\u011b\u0159\u00edm na p\u0159\u00edstupov\u00fd syst\u00e9m: zakl\u00e1d\u00e1n\u00ed z\u00f3n, datab\u00e1ze osob, p\u0159i\u0159azen\u00ed \u010dip\u016f a synchronizace opr\u00e1vn\u011bn\u00ed na kontrol\u00e9r.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tato s\u00e9rie \u010dl\u00e1nk\u016f vznik\u00e1 trochu neobvykle \u2013 p\u00ed\u0161u ji z\u00e1rove\u0148 jako pr\u016fvodce pro \u010dten\u00e1\u0159e i jako vlastn\u00ed pozn\u00e1mky. Dahua DSS Express se u\u010d\u00edm za pochodu, prvn\u00ed instalaci provozuji na star\u00e9m serveru, kter\u00fd mi zbyl (politika re-use m\u00edsto n\u00e1kupu nov\u00e9ho HW). \u010casem pl\u00e1nuji \u010distou instalaci na lep\u0161\u00edm hardwaru \u2013 bazarov\u00fd 2\u00d7 Xeon s 64 GB RAM [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":845,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[87],"tags":[95,96],"class_list":["post-839","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-kamery-dahua","tag-dahua","tag-dss-express"],"_links":{"self":[{"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/posts\/839","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=839"}],"version-history":[{"count":3,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/posts\/839\/revisions"}],"predecessor-version":[{"id":848,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/posts\/839\/revisions\/848"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=\/wp\/v2\/media\/845"}],"wp:attachment":[{"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=839"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=839"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/loxoneworks.cz\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}